UPS Assistant 2.2.0.64![]() ![]() |
UPS Assistant is intended for monitoring of status of the Uninterruptible Power Supply (UPS), connected to a computer through USB- or COM-port and supporting the Megatec/Centralion protocol (Ippon, Mustek, Sven, Inelt).
Author: Alexey V.Voronin
License: Freeware
Requires: Windows 2000, XP, 2003, Vista (x86 and x64), Windows 7 (x86 and x64).
UPS Assistant is provided "as is", with no warranties whatsoever.
License For Customer Use of Alexey V.Voronin UPS Assistant Software
![]() |
Supported UPSes |
Downloads:
MD5: 83c4960302a5844170e730a03d91f51fNumber of downloads: 893
UPS Assistant 2.2.0.64 - 593 KB (released January 31, 2010) - Download From http://www.hexy.name
Nighty Builds
Nighty builds of UPS Assistant are provided for testing purposes only.
Donate!Features UPS Assistant -
* following UPSes are supported (tab "UPS Information"):
:-
- VID=$06DA, PID=$0003 - IPPON Mustek/Sven;
- VID=$0F03, PID=$0001 - Inelt
- VID=$0665, PID=$5161 - IPPON/Mustek/Sven
(connection type is displayed by picture in the program window: USB
or COM
)
AVR:
TRIM - UPS is trimming incoming voltage (called "buck" in some hardware)
BYPASS - UPS bypass circuit is active - no battery protection is available
BOOST - UPS is boosting incoming voltage
OL/OB/OFF - UPS modes:
- OL - on line
- OB - on battery (inverter is providing load power)
- OFF - UPS is offline and is not supplying power to the load
* logging accidents with the possibility of clearing (tab "UPS Status")
and saving to a text file 

* submitting reports on the status of the UPS with a given frequency and warnings of emergency situations via e-mail (tab "Settings")
(requires prior connection to the Internet)

Host - SMTP server address
Port - SMTP server port (default 25)
Login - account name of SMTP server
Password - account password of SMTP server
From - sender e-mail address
E-Mail - recipient e-mail address
Subject - subject of test message
The choice of parameters to be included in the report, and emergency situations in which sends a warning:

The button
to send test messages.
- the inclusion of sending reports on the status of UPS e-mail with a given frequency
- the inclusion of sending warnings to emergency situations via e-mailExample report on the status of UPS:
-
Subject: Report - 29.06.2008 20:06:04
Report - 29.06.2008 20:06:04
VID: 0x06DA PID: 0x0003 Product: USB UPS
I/P Voltage = 221.8 V
I/P Fault Voltage = 222.3 V
O/P Voltage = 222.3 V
O/P Current = 028 %
I/P Frequency = 49.9 Hz
Battery Voltage = 13.5 V
Temperature = 25.0°C
UPS Status = 00001001
-
Subject: Warning - Power fail
Warning - 29.06.2008 20:26:26 Power fail
VID: 0x06DA PID: 0x0003 Product: USB UPS

Server Name - name of the computer receiving messages (default, the name of your computer)
The choice of parameters to be included in the report, and emergency situations in which sends a warning:

The button
to send test messages.
- the inclusion of sending reports on the status of UPS with a given frequency
- the inclusion of sending warnings to emergency situationsExample report on the status of UPS:

An example of an emergency warning:

* toggle UPS beeper

* UPS battery test in 10 seconds

* UPS battery test for specified time period
)program asks to specify the duration of the test

(this command is not supported by all UPS)
* test until battery low
)(this command is not supported by all UPS)
* cancel Test
)(this command is not supported by all UPS)
* suspend
, hibernate
, shutdown
(force -
)* suspend, hibernate, shutdown at power fail (force -
):- at a voltage reduction on battery below admissible

- through the set interval of time

This may automatically switch off the UPS (delayed 5 minutes) when the emergency shutdown or move into hibernation and then automatically UPS activate when restoration of power failure - "UPS Shutdown" - command "S" ( "Shut Down Command") (Note - this command is not supported by all UPS)

* choice of used commands of Megatec/Mustek protocol

(for the changes to take effect must restart the program)
* autorun with Windows

* adjustment of an interval of updating of the information on a status of the UPS

* possibility to turn off the tooltips - "Balloon Hints"

* save setiings in Windows registry:
- on click the button

- at an exit from the program

* HTTP-server to receive reports via the Web with the possibility of user authentication (tab "Settings")

- Enabled - on / off HTTP-server
- Port - port of HTTP-server
- Authentication - the use of user authentication when accessing HTTP-server
- User - user name (if you are using authentication)
- Password - user password (if you are using authentication)

Start of the program
If the UPS is connected to a COM-port, then when you first start the program requests the number of COM-port
.If the "UPS Rating Information" command ( "F") is not supported or is disabled, the program requests that the battery voltage
.At start the program is turned off in tray and displays the information on a current status of the UPS three possible icons:
- power O.K.;
- AVR;
- power failIf the UPS is supported, then hint appears: USB:
, COM:
.When you right-click on the icon in the system tray pop-up menu appears:

"Restore" - expand the program window
"Minimize" - minimize window
"Exit" - exit from program.
When you click the left mouse button on the button
in the window title program does not close, but rolled in the system tray.
Screenshots
Power O.K.Power Fail
What is new in UPS Assistant 2.2.0.64
* changed interface+ added support for UPS with battery voltage of 96 V (for example, Ippon Smart Winner 3000)
* added recognition of operating systems Windows 7/Windows Server 2008 R2
What is new in UPS Assistant 2.1.1.56
+ added ability to send reports and warnings in the form of network messages in the LAN (with support for Windows Vista / Server 2008) (tab "LAN")
* fixed SMTP-authentication
What is new in UPS Assistant 2.1.0.55
+ added ability to disable the action to delay or reduce the battery voltage when the accident power failure mains
+ added a fictitious action "Nothing" to delay or reduce the battery voltage when mains power failure

+ added ability to run external program "Run program" with waiting for it to complete before performing the designated action to delay or reduce the battery voltage when mains power failure

+ added time setting off UPS when the emergency shutdown within 1 .. 60 minutes

* increased the maximum time delay in the emergency AC power to 3 * 3600 = 10800 seconds
* fixed displaying of tray icon in different modes
What is new in UPS Assistant 2.0.2.54
+ added the ability to automatically switch off the UPS (5 minutes delayed) with emergency shutdown (shutdown or go into sleep mode when accident power failure) and subsequent automatic activation of UPS in the restoration of power failure - "UPS Shutdown" - command "S" ( "Shutdown Command ") (Note - this command is not supported by all UPS)+ added the ability to disable tooltips - "Balloon Hints"
* improved reporting and sending alerts via SMTP
What is new in UPS Assistant 2.0.1.49
* revised algorithm exchange of information with the UPS and mechanism of threads synchronization - eliminated the program hangs and failures+ added support for connecting to the UPS through a COM-port
+ added support for UPSes Mustek PowerMust 424/636/848
+ added command "Test until battery low" ("TL")
+ added command "Test for specified time period" ("T")
+ added command "Cancel Test" ("CT")
+ added support for command "I" ("UPS Information"), allowing to obtain information about the manufacturer ("Mfr."), model ("Model") and firmware version ("Ver.")
+ added possibility to set used command of protocol Megatec
+ when you click on the button "x" in the title window rolled in the system tray, and the exit occurs on the command "Exit" context menu when right-click on the icon in the tray
+ added balloon hints to the information on the status of the UPS
What is new in UPS Assistant 1.3.0.33
* tested under Windows 7 Beta Build 7000 x64* added to the choice of events, when a warning is sent by e-mail
* fixed a bug than caused the access violation with UPS when when disconnected or unavailable UPS
* tested under Windows 7 Beta Build 7000 x86
* added displaying OS version
* tested under Windows Server 2008 x86
* updated versions of JCL to 1.102 and JVCL to 3.34
* added preventing the launching of multiple copies of the program
* added editing of value "Min. Voltage" when you press keys "Arrow Up" (+0,1 V), "Page Up" (+1 V), "Arrow Down" (-0,1 V), "Page Down" (-1 V)
* added HTTP server to receive reports via the Web with possibility of user authentication
* added choice of parameters to be included in the e-mail- or Web-report
* added editing of values "Full Battery Voltage" and "Empty Battery Voltage" when you press keys "Arrow Up" (+0,1 V), "Page Up" (+1 V), "Arrow Down" (-0,1 V), "Page Down" (-1 V)
* fixed a bug with displaying of UPS modes ("Power fail", "AVR", "Battery Low")
* fixed a bug than caused the loss of connection with UPS when you press buttons "Stop" and "Start"
* fixed a bug that caused the leakage of handles
* fixed a bug that caused the reset of values "Full Battery Voltage" and "Empty Battery Voltage" with their editing
What is new in UPS Assistant 1.2.0.26
* corrected battery parameters correction depending on its nominal voltage* increased maximum possible time delay in switching off at power fail until 3600 s (60 min)
* added saving in program settings actions at power fail ( "Power fail" -> "Action")
What is new in UPS Assistant 1.2.0.19
* added displaying of AVR mode - BOOST, TRIM or BYPASS* added displaying of minimum and maximum (in on line mode) input voltage of UPS
* added displaying mode of operation of UPS - OL, OB or OFF
* added displaying of nominal voltage of battery
* supported battery with nominal voltage of 12, 24, 36 and 48 V
* possible manual tuning voltage for fully charged and fully discharged battery
* added displaying of battery charge level (percentage)
What is new in UPS Assistant 1.1.0.17
* added possibility of sending reports and alerts by e-mail* changed logging of events - logged only important events, added the possibility of cleaning log and saving log on file
* changed site address program - http://www.hexy.name/UPSAssistant.html
Feedbacks
w_w
. , ...
Pavel
Very good !!
Flid
!
peter
, UPS Assistant - , , , "", .
Redy
. .
Alex AC
, .
madmaximka
. . +1
UPS Assistant ,
, !
VladMgn
...
SHura
, , ( Inelt-)...
. , ...
Pavel
Very good !!
Flid
!
peter
, UPS Assistant - , , , "", .
Redy
. .
Alex AC
, .
madmaximka
. . +1
UPS Assistant ,
, !
VladMgn
...
SHura
, , ( Inelt-)...
Leave your feedback!
RU
EN











